Cell Block Preparation from Cytology Specimen with Predominance of Individually Scattered Cells
Published on: July 21, 2009
Conventional versus Liquid-based Cytology: "Man versus Machine"
Saleem Pathuthara1, Swati Dighe1, Maya Uke1
1Department of Cytopathology, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Mumbai, Maharashtra, India.
Liquid-based cytology (LBC) and conventional smears (CS) showed similar diagnostic adequacy. While LBC offers a cleaner background, CS excels in detecting inflammation and organisms, with careful technique crucial for both methods.
Area of Science:
- Cytopathology
- Diagnostic cytology
- Gynecological and non-gynecological sample analysis
Background:
- Liquid-based cytology (LBC) potentially improves sample adequacy and quality over conventional smears (CS).
- LBC offers a cleaner background and monolayer cell distribution.
- Conventional smears (CS) are a long-established cytological technique.
Purpose of the Study:
- To compare the diagnostic quality and yield of LBC versus CS in routine cytological investigations.
- To evaluate specific parameters including cellularity, background, inflammation, and malignancy detection.
- To assess preparation and screening time differences between the two methods.
Main Methods:
- Retrospective study of 306 samples (gynecological, non-gynecological, FNAC) from 2019-2020.
- Paired sample collection: two samples per patient processed via CS and LBC (ThinPrep®).
- Comparison of adequacy, quality, representativeness, inflammation, hemorrhage, necrosis, preservation, reactive changes, organisms, atypia/dysplasia/malignancy, and processing/screening time.
Main Results:
- No statistically significant difference in adequacy, representativeness, reactive changes, preservation, or malignancy detection.
- Conventional smears (CS) showed better cellularity and diagnosis of inflammation and organisms.
- Liquid-based cytology (LBC) yielded a significantly cleaner background (P = 0.0005).
Conclusions:
- CS is comparable to LBC in adequacy and malignancy detection, with potential for improvement via careful technique.
- CS demonstrated superiority in detecting organisms and inflammation.
- LBC offers advantages in smear quality and screening time but incurs higher costs and longer processing times, making it suitable for specific laboratory settings.
Related Concept Videos
Flow Cytometry
In...
Immunocytochemistry and Immunohistochemistry
These...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...