Patient and physician radiation exposure during minimally invasive lumbar decompression: A prospective assessment of

Nagy Mekhail1, Krista Topalsky2, Erin Templeton1

  • 1Pain Management Department, Cleveland Clinic, Cleveland, Ohio, USA.

Abstract

Insights

Minimally invasive lumbar decompression (mild®) for spinal stenosis shows low radiation exposure for patients and physicians. This fluoroscopic procedure

Area of Science:

  • Interventional Pain Management
  • Neurosurgery
  • Radiology

Background:

  • Minimally invasive lumbar decompression (mild®) is a growing treatment for lumbar spinal stenosis (LSS).
  • The procedure utilizes fluoroscopic guidance, posing potential radiation risks.
  • Hypertrophic ligamentum flavum is a common cause of LSS addressed by mild®.

Purpose of the Study:

  • To quantify patient and physician radiation exposure during the mild® procedure.
  • To compare radiation exposure from mild® to other fluoroscopically guided interventions.

Main Methods:

  • A single physician performed mild® on 41 patients between October 2019 and December 2021.
  • Physician radiation exposure was monitored using a dosimeter.
  • Key metrics included fluoroscopy time and radiation dose per procedure and per level.

Main Results:

  • Mean patient fluoroscopy time was 2.1 minutes per unilateral level.
  • Mean patient radiation skin exposure was 1.1 mGy/cm².
  • Physician exposure was low, with annual limits unlikely to be exceeded after 610 procedures.

Conclusions:

  • Radiation exposure for both patients and physicians during the mild® procedure is minimal.
  • Compared to similar procedures, mild® demonstrates favorable radiation safety profiles.