Purpose:
To evaluate the current published literature on the utility of the 10-2 visual field (VF) testing strategy for the evaluation and management of early glaucoma, defined here as mean deviation (MD) better than -6 decibels (dB).
Methods:
A search of the peer-reviewed literature was last conducted in June 2023 in the PubMed database. Abstracts of 986 articles were examined to exclude reviews and non-English-language articles. After inclusion and exclusion criteria were applied, 26 articles were selected, and the panel methodologist rated them for strength of evidence. Thirteen articles were rated level I, and 8 articles were rated level II. The 5 level III articles were excluded. Data from the 21 included articles were abstracted and reviewed.
Results:
The central 12 locations on the 24-2 VF test grid lie within the central 10 degrees covered by the 10-2 VF test. In early glaucoma, defects detected within the central 10 degrees generally agree between the 2 tests. Defects within the central 10 degrees of the 24-2 VF test can predict defects on the 10-2 VF test, although the 24-2 may miss defects detected on the 10-2 VF test. In addition, results from the 10-2 VF test show better association with findings from OCT scans of the macular ganglion cell complex. Modifications of the 24-2 test that include extra test locations within the central 10 degrees improve detection of central defects found on 10-2 VF testing.
Conclusions:
Evidence to date does not support routine testing using 10-2 VF for patients with early glaucoma. However, early 10-2 VF testing may provide sufficient additional information for some patients, particularly those with a repeatable defect within the central 12 locations of the standard 24-2 VF test or who have inner retinal layer thinning on OCT scans of the macula.
Financial Disclosure(S):
Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.