A high-performance standalone planar FAIMS system for effective detection of chemical warfare agents via TSPSO
Jie Hao1, Rong Feng2, Junhui Li2
1Institute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Ningbo University, Ningbo, 315211, PR China; Zhenhai Institute of Mass Spectrometry, Ningbo, 315211, PR China; Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo, 315211, PR China.
Abstract:
A high-performance standalone planar field asymmetric waveform ion mobility spectrometry (p-FAIMS) system with a deconvolution algorithm (two-step particle swarm optimization algorithm, TSPSO) for overlapping peaks was developed to effectively detect chemical warfare agents (CWAs). Four CWA simulants were applied in this study to systemically evaluate the performance of the standalone p-FAIMS system. The experimental results showed that each CWA simulant in the mixture can be positively identified by carefully comparing the compensation voltage (CV) value of each peak in the FAIMS spectra for the mixture to the ones in the spectra acquired by using the same FAIMS system for the pure CWA simulant standards. The FAIMS spectrum of the CWA simulant mixture might consist of multiple overlapping peaks, which would be difficult to accurately determine the CV value for each CWA simulant peak. This problem has been effectively resolved in this study by deconvoluting the overlapping peaks via the TSPSO algorithm. As the effective peak deconvolution via TSPSO requires the degree of overlap between each FAIMS peak to be lower than a specific value, the flow rate of FAIMS carrier gas was decreased to further improve the resolution of the p-FAIMS system. After the accurate deconvolution, the resolution of original FAIMS spectrum can also be enhanced to achieve baseline separation by using TSPSO algorithm to narrow the peak width of each peak. The experimental results in this study demonstrated the possibility of using TSPSO algorithm to achieve high-resolution on a typically low-resolution standalone FAIMS. The concept in this study can potentially be applied to any low-resolution instruments to achieve high-resolution results.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
11:00Hand Controlled Manipulation of Single Molecules via a Scanning Probe Microscope with a 3D Virtual Reality Interface
Published on: October 2, 2016
Related Concept Videos
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....