Related Experiment Video
Updated: Jul 8, 2025

Assessment of Static Graviceptive Perception in the Roll-Plane using the Subjective Visual Vertical Paradigm
Published on: April 28, 2020
Determining the effects of AR/VR HMD design parameters (mass and inertia) on cervical spine joint torques
Amanda N Astrologo1, Sarah Nano1, Elizabeth M Klemm1
1Department of Bioengineering, Northeastern University, Boston, MA, USA.
Abstract:
This study aimed to determine gravitational and dynamic torques and muscle activity of the neck across a series of design parameters of head mounted displays (mass, center of mass, and counterweights) associated with virtual and augmented reality (VR/AR). Twenty young adult participants completed five movement types (Slow and Fast Flexion/Extension and Rotation, and Search) while wearing a custom-designed prototype headset that varied the three design parameters: display mass (0, 200, 500, and 750 g), distance of the display's center of mass in front of the eyes (approximately 1, 3, and 5 cm anteriorly), and counterweights of 0, 166, 332, and 500 g to balance the display mass of 500 g at 7 cm. Inverse dynamics of a link segment model of the head and headset provided estimates of the torques about the joint between the skull and the occiput-first cervical vertebrae (OC1) and joint between the C7 and T1 vertebrae (C7). Surface electromyography (EMG) measured bilateral muscle activity of the splenius and upper trapezius muscles. Adding 750 g of display mass nearly doubled root mean square joint torques across all movement types. Increasing the distance of the display mass in front of the eyes by 4 cm increased torques about OC1 for the Slow and Fast Rotation and Search movements by approximately 20%. Adding a counterweight decreased torques about OC1 during the rotation and search tasks but did not decrease the torques experienced in the lower cervical spine (C7). For the flexion/extension axis, the magnitude of the dynamic torque component was 20% or less of the total torque experienced whereas for the rotation axis the magnitude of the dynamic torque component was greater than 50% of the total torque. Surface EMG root mean square values significantly varied across movement types with the fast rotation having the largest values; however, they did not vary significantly across the headset configurations.
Related Concept Videos
Articulations of the Vertebral Column
Bending and Torsional Moments
The reaction developed in a structural element when subjected to an external force causes the element to bend. When a structural element bends upwards, it creates compressive normal forces on the top and tensile normal forces on the bottom, resulting in a couple that determines the bending...
Deformation in a Circular Shaft
Kinematic Equations for Rotation
For instance, imagine a point A on a rigid body engaged in circular motion. The translational velocity of this particular point can be calculated by taking the time derivatives of the displacement equation, which essentially measures the...
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...