Reproducibility of inverse gas chromatography under infinite dilution: Results and interpretations of an
Johanna Sygusch1, Ralf Duempelmann2, Ralf Meyer3
1Helmholtz-Zentrum Dresden-Rossendorf, Helmholtz Institute Freiberg for Resource Technology, Chemnitzer Straße 40, Freiberg 09599, Germany.
Abstract:
Over the last years, inverse gas chromatography (IGC) proved to be a versatile and sensitive analytical technique for physicochemical properties. However, the comparability of results obtained by different users and devices remains a topic for debate. This is the first time, an interlaboratory study using different types of IGC instruments is reported. Eight organizations with different IGC devices defined a common lab measurement protocol to analyse two standard materials, silica and lactose. All data was collected in a standard result form and has been treated identically with the objective to identify experimentally observed differences and not potentially different data treatments. The calculated values of the dispersive surface energy vary quite significantly (silica: 22 mJ/m2 - 34 mJ/m2, lactose 37 mJ/m2 - 51 mJ/m2) and so do the ISP values and retention volumes for both materials. This points towards significant and seemingly undiscovered differences in the operation of the instruments and the obtained underlying primary data, even under the premise of standard conditions. Variations are independent of the instrument type and uncertainties in flow rates or the injected quantities of probe molecules may be potential factors for the differences. This interlaboratory study demonstrates that the IGC is a very sensitive analytical tool, which detects minor changes, but it also shows that for a proper comparison, the measurement conditions have to be checked with great care. A publicly available standard protocol and material, for which this study can be seen as a starting point, is still needed to judge on the measurements and the resulting parameters more objectively.
More Related Videos
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...