Related Experiment Video
Updated: Jul 8, 2025

Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels
Published on: May 26, 2023
Preliminary experience with transcatheter closure of wind-sock-like perimembranous ventricular septal defects using
Ming Chern Leong1, Xin Yi Hoo1, Mazeni Alwi1
1Paediatric & Congenital Heart Centre, Institute Jantung Negara (National Heart Institute), Kuala Lumpur, Malaysia.
Abstract:
Amplatzer Vascular Plug IV (Abbott, USA) is usually used for the occlusion of abnormal tortuous vessels and has not been tried for the transcatheter closure of perimembranous ventricular septal defects with wind-sock morphology. Here, we report on three successful cases of perimembranous ventricular septal defect transcatheter closure using Amplatzer Vascular Plug IV. We did not observe residual shunting or new onset of complications during follow up. These preliminary positive results advocate the application and suitability of Amplatzer Vascular Plug IV for closing wind-sock-like perimembranous ventricular septal defects.