Online verification and management scheme of gateway meter flow in the power system by machine learning
Chong Li1, Hao Wang1, Hongtao Shen1
1State Grid Hebei Marketing Service Center, Shijiazhuang, HeBei, China.
Abstract:
Currently, the calibration of electric energy meters often involves manual meter reading, dismantling inspection, or regular sampling inspection conducted by professionals. To improve work efficiency and verification accuracy, this research integrates machine learning into the scheme of online verification and management of gateway meter flow in the power system. The approach begins by applying the Faster Region Convolutional Neural Network (Faster-RCNN) model and the Single Shot MultiBox Detector (SSD) model to the recognition system for dial readings. Then, the collected measurement data is pre-processed, excluding data collected under light load conditions. Next, an estimation error model and a solution equation for the electricity meter are established based on the pre-processed data. The operation error of the electricity meter is estimated, and the estimation accuracy is verified using the limited memory recursive least squares algorithm (LMRLSA). Furthermore, business assistant decision-making is carried out by combining the remote verification results with the estimation outcomes. The proposed dial reading recognition system is tested using 528 images of meter readings, achieving an accuracy of 98.49%. In addition, the influence of various parameters on the error results of the electricity meter is also explored. The results demonstrate that a memory length ranging from 600 to 1,200 and a line loss error of less than 5% yield the most suitable accuracy for estimating the electricity meter error. Meanwhile, it is advisable to remove measurement data collected under light load to avoid unnecessary checks. The experiments manifest that the proposed algorithm can properly eliminate the influence of old measurement data on the error parameter estimation, thereby enhancing the accuracy of the estimation. The adjustment of the memory length ensures real-time performance in estimating meter errors and enables online monitoring. This research has certain reference significance for achieving the online verification and management of gateway meter flow in the power system.
Related Concept Videos
The Power Flow Problem and Solution
Control of Power Flow
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Fast Decoupled and DC Powerflow
Maximum Power Flow and Line Loadability
Signal Flow Graphs
In a signal-flow graph, branches denote the system's transfer functions, while nodes represent the signals. The direction of signal flow is indicated by arrows, with the corresponding...