Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Headspace sampling-gas chromatograph-mass spectrometer as a screening method to thermally extract fireground
Adhiraj Shinde1, R Bryan Ormond1
1North Carolina State University, Raleigh, North Carolina.
Abstract:
Firefighters are at a 1.5 to 2 times greater risk of contracting certain types of cancers as compared to the general population. After preliminary studies, it was evident that contaminated turnout gear and ensemble elements could be linked to heightened cancer rates amongst firefighters. Compounds such as polycyclic aromatic hydrocarbons (PAHs), perfluorinated compounds, phenols, phthalates, brominated flame retardants, dioxins, volatile organic compounds, and many others are present in the contaminated gear, of which many are known carcinogens. A setup of headspace sampler-gas chromatograph-mass spectrometer was used to measure the off-gassing of the fabric samples taken from retired field-contaminated turnout jackets. The fabric samples were exposed to a specific temperature and allowed to equilibrate for a fixed time in the HS. A custom reference mix of phenols, phthalates and PAHs was put together to develop standard calibration curves. The compounds off-gassing from the outer shell, thermal liner and the moisture barrier were analyzed and the masses of certain marker compounds were calculated based of the standard calibration curves. The technique could be used as a screening method to thermally extract contaminants from field-contaminated firefighter turnout materials such as jackets, pants, gloves, and so on.
More Related Videos
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-II
Atomic Absorption Spectroscopy: Atomization Methods
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...