Observation of a temperature dependent anomaly in the UV translucency of milk useful for UV-C preservation techniques

Jaayke L Fiege1, Benedikt Woll2, Stefan Hebig2

  • 1Department of Food Technology and Bioprocess Engineering, Max Rubner-Institut, Federal Research Institute of Nutrition and Food, 76131, Karlsruhe, Germany. jaayke.fiege@mri.bund.de.

Scientific Reports
|December 11, 2023
PubMed

Milk fat globules and casein micelles are the dispersed particles of milk that are responsible for its typical white turbid appearance and usually make it difficult to treat with modern ultraviolet light (UV) preservation techniques. The translucency of milk depends largely on the refractive indices of the dispersed particles, which are directly affected by temperature changes, as incorporated triglycerides can crystallize, melt or transition into other polymorphs. These structural changes have a significant effect on the scattering properties and thus on the UV light propagation in milk, especially by milk fat globules. In this study, a temporary minimum in the optical density of milk was observed within UV wavelength at 14 °C when heating the milk from 6 to 40 °C. This anomaly is consistent with structural changes detected by a distinct endothermic peak at 14 °C using differential scanning calorimetry. Apparently, the optical density anomaly between 10 and 20 °C disappears when the polymorphic transition already has proceeded through previous isothermal equilibration. Thus, melting of equilibrated triglycerides may not affect the RI of milk fat globules at ca. 14 °C as much as melt-mediated polymorphic transitioning. An increased efficiency of UV-C preservation (254 nm) at the translucency optimum was demonstrated by temperature-dependent microbial inactivation experiments.

Related Concept Videos

Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview01:02

Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview

Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material,  molecules absorb light depending on the energy required for...
2.7K
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.3K
UV–Vis Spectroscopy: Beer–Lambert Law01:09

UV–Vis Spectroscopy: Beer–Lambert Law

The Beer-Lambert law describes the relationship between absorbance and concentration, which combines the principles established by scientists Johann Heinrich Lambert and August Beer. Lambert's law states that when light passes through a medium, the loss in intensity is directly proportional to the original intensity and the path length of the light. Beer's law proposed that the transmittance of a solution remains constant if the product of concentration and path length is constant. The...
2.8K
Sample Handling01:02

Sample Handling

Transportation of samples from the collection point to the laboratory, as well as storage and preservation techniques, are crucial for maintaining sample integrity and ensuring accurate and reliable test results.
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...