Boosting Algorithms based Cuff-less Blood Pressure Estimation from Clinically Relevant ECG and PPG Morphological
Abstract:
Blood Pressure (BP) is often coined as a critical physiological marker for cardiovascular health. Multiple studies have explored either Photoplethysmogram (PPG) or ECG-PPG derived features for continuous BP estimation using machine learning (ML); deep learning (DL) techniques. Majority of those derived features often lack a stringent biological explanation and are not significantly correlated with BP. In this paper, we identified several clinically relevant (bio-inspired) ECG and PPG features; and exploited them to estimate Systolic (SBP), and Diastolic Blood Pressure (DBP) values using CatBoost, and AdaBoost algorithms. The estimation performance was then compared against popular ML algorithms. SBP and DBP achieved a Pearson's correlation coefficient of 0.90 and 0.83 between estimated and target BP values. The estimated mean absolute error (MAE) values are 3.81 and 2.22 mmHg with a Standard Deviation of 6.24 and 3.51 mmHg, respectively, for SBP and DBP using CatBoost. The results surpassed the Advancement of Medical Instrumentation (AAMI) standards. For the British Hypertension Society (BHS) protocol, the results achieved for all the BP categories resided in Grade A. Further investigation reveals that bio-inspired features along with tuned ML models can produce comparable results w.r.t parameter-intensive DL networks. ln(HR × mNPV), HR, BMI index, ageing index, and PPG-K point were identified as the top five key features for estimating BP. The group-based analysis further concludes that a trade-off lies between the number of features and MAE. Increasing the no. of features beyond a certain threshold saturates the reduction in MAE.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure