Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
Published on: April 13, 2013
Demographic Information Fusion Using Attentive Pooling In CNN-GRU Model For Systolic Blood Pressure Estimation
Abstract:
Fusing demographic information into deep learning models has become of interest in recent end-to-end cuff-less blood pressure (BP) estimation studies in order to achieve improved performance. Conventionally, the demographic feature vector is concatenated with the pooled embedding vector. Here, using an attention-based convolutional neural network-gated recurrent unit (CNN-GRU), we present a new approach and fuse the demographic information into the attentive pooling module. Our results demonstrate that, under calibration-based testing protocol, the proposed approach provides improved systolic blood pressure (SBP) estimation accuracy (with R2=0.86 and mean absolute error (MAE)=4.90 mmHg) compared to both the baseline model with no demographic information fused, and the conventional approach of fusing demographic information. Our work showcases the feasibility of using attention-based methods to combine demographic features with deep learning models, and suggests new ways for fusing demographic information in deep learning models to achieve improved BP estimation accuracy.
More Related Videos
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: