Camera Wavelength Selection for Multi-wavelength Pulse Transit Time based Blood Pressure Monitoring
Abstract:
Multi-wavelength pulse transmit time (MV-PTT) is a potential tool for remote blood pressure (BP) monitoring. It uses two wavelengths, typically green (G) and near-infrared (NIR), that have different skin penetration depths to measure the PTT between artery and arterioles of a single site of the skin for BP estimation. However, the impact of wavelength selection for MV-PTT based BP calibration is unknown. In this paper, we explore the combination of different wavelengths of camera photoplethysmography for BP measurement using a modified narrow-band camera centered at G-550/R-660/NIR-850 nm, especially focused on the comparison between G-R (full visible) and G-NIR (hybrid). The experiment was conducted on 17 adult participants in a dark chamber with their BP significantly changed by the protocol of ice water stimulation. The experimental results show that the MV-PTT obtained by G-NIR has a higher correlation with BP, and the fitted model has lower MAE in both the systolic pressure (5.78 mmHg) and diastolic pressure (6.67 mmHg) than others. It is confirmed that a hybrid wavelength of visible (G) and NIR is still essential for accurate BP calibration due to their difference in skin penetration depth that allows proper sensing of different skin layers for this measurement.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:12Real-Time Monitoring of Neurocritical Patients with Diffuse Optical Spectroscopies
Published on: November 19, 2020
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring pulse
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement