Related Experiment Video
Updated: Jul 8, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
A Novel Form Factor For PPG-based Blood Pressure Monitoring
Abstract:
Blood pressure (BP) is one of the four main vital signs in medicine and may be a useful signal for wellness tracking and for user-aware interfaces in human-computer interaction. The current standard for BP measurement uses cuff-based devices that block an artery temporarily to get a single, discrete measurement of BP. Recently, there have been significant efforts to measure correlates of BP continuously and non-invasively from relevant signals like photoplethysmography (PPG), which responds to volumetric changes in arteries due to blood pulsations. In this paper, we explore a novel setup with two points of instrumentation, one on the head and a second on the wrist, for recording PPG and estimating the pulse wave velocity, which is a major correlate of BP, along with other waveform-related features. We prospectively tested the device on 10 subjects who followed a protocol for the deliberate variation of BP while ground truth measurements were taken using a reference cuff-device. Generic absolute BP models, which use the collected data for leave-one-subject-out cross-validation, yielded an error of -0.14 ± 7.3 mmHg for systolic BP (SBP) and -0.21±6.7 mmHg for diastolic BP (DBP), which are within the regulatory limits of 5 ± 8 mmHg. Notably, the correlation between the predicted BPs and the ground truth BPs was higher for SBP (r = 0.74, p < 0.001) than for DBP (r = 0.34, p < 0.001). The results show that the proposed form factor can extract BP-related features that could be used for continuous, cuff-less BP monitoring.
More Related Videos
10:03Conformable Wearable Electrodes: From Fabrication to Electrophysiological Assessment
Published on: July 22, 2022
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...