Physical Artificial Arterial Pulse System for Development and Testing of PPG-Based Sensors
Abstract:
A physical system to generate a PPG-mimicking signal was designed and validated using everyday low-cost components to aid in medical sensor design. The pulse waveform was created by driving a working fluid into a silicone tube and changing the pressure within it. The corresponding waveform mimics a PPG signal through an artery, is adaptable, and repeatable. The working fluid is interchangeable allowing for change of blood analyte concentrations for development and testing of PPG-based sensors. The system was validated by black ink water compared to water and air compared to water testing to confirm optical transparency of the tube. The produced PPG signal, pulse rate and pressure change were compared to that seen in subjects. Optical transparency for 660 nm - 1550 nm wavelengths of light was validated with the signal, pulse rate and total compliance matching subject data. Thus, the system can mimic arterial pulses, creating a valid PPG signal that can be detected by PPG-based sensors.Clinical Relevance- Provides a low-cost, adaptable, physical PPG signal generator for research and development of optical medical sensor technologies.
More Related Videos
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Pulse
The pulse serves as a clinical...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse Assessment Sites
Special considerations while measuring pulse