Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Viscosity of Fluid01:19

Viscosity of Fluid

428
Viscosity measures the resistance a fluid offers to flow and deformation. It results from internal friction between layers of fluid moving relative to one another. Dynamic viscosity, denoted by the Greek letter mu (μ), quantifies the force needed to move one fluid layer over another. For Newtonian fluids like water and air, the relationship between the shearing stress and the rate of shearing strain is linear, meaning their viscosity remains constant regardless of the applied stress.
428
Pressure Variation in a Fluid at Rest01:11

Pressure Variation in a Fluid at Rest

256
In a fluid at rest, the pressure at any point beneath the fluid surface depends solely on the depth, not on the container's shape or size. This principle, known as hydrostatic pressure, arises because, in stationary fluids, there is no acceleration, meaning the forces within the fluid balance out. Only vertical forces, caused by the weight of the fluid above, contribute to pressure changes with depth.
When measuring pressure at two different levels within the fluid, the difference in...
256
Accelerating Fluids01:17

Accelerating Fluids

1.1K
When a fluid is in constant acceleration, the pressure and buoyant force equations are modified. Suppose a beaker is placed in an elevator accelerating upward with a constant acceleration, a. In the beaker, assume there is a thin cylinder of height h with an infinitesimal cross-sectional area, ΔS.
The motion of the liquid within this infinitesimal cylinder is considered to obtain the pressure difference. Three vertical forces act on this liquid:
1.1K
Fluid Mosaic Model01:19

Fluid Mosaic Model

11.9K
Scientists identified the plasma membrane in the 1890s and its principal chemical components (lipids and proteins) by 1915. The model for plasma membrane structure, proposed in 1935 by Hugh Davson and James Danielli, was the first model to be widely accepted in the scientific community. The model was based on the plasma membrane's "railroad track" appearance in early electron micrographs. Davson and Danielli theorized that the plasma membrane's structure resembled a sandwich...
11.9K
The Fluid Mosaic Model01:34

The Fluid Mosaic Model

148.0K
The fluid mosaic model was first proposed as a visual representation of research observations. The model comprises the composition and dynamics of membranes and serves as a foundation for future membrane-related studies. The model depicts the structure of the plasma membrane with a variety of components, which include phospholipids, proteins, and carbohydrates. These integral molecules are loosely bound, defining the cell’s border and providing fluidity for optimal function.
148.0K
Viscosity01:17

Viscosity

5.9K
When water is poured into a glass, it falls freely and quickly, whereas if honey or maple syrup is poured over a pancake, it flows slowly and sticks to the surface of the container. This difference in the flow of different kinds of liquids arises due to the fluid friction between the liquid layers and the liquid and the surrounding material. This property of fluids is called fluid viscosity. In this example, water has a lower viscosity than honey and maple syrup.
The SI unit of viscosity is...
5.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Machine learning-based skin nerve morphometry for diabetic neuropathy: diagnostic and clinical implications.

Brain communications·2026
Same author

Classification of lung nodules in CT images based upon a multiplane dense inception network.

Medical physics·2026
Same author

Pulmonary Nodule Classification Using a Multiview Residual Selective Kernel Network.

Journal of imaging informatics in medicine·2024
Same author

Automated Stroke Lesion Segmentation in Rat Brain MR Images Using an Encoder-Decoder Framework.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2023
Same author

RU-Net: skull stripping in rat brain MR images after ischemic stroke with rat U-Net.

BMC medical imaging·2023
Same author

Segmentation of Rat Brains and Cerebral Hemispheres in Triphenyltetrazolium Chloride-Stained Images after Stroke.

Sensors (Basel, Switzerland)·2021

Related Experiment Video

Updated: Jul 8, 2025

Confocal Imaging of Confined Quiescent and Flowing Colloid-polymer Mixtures
10:56

Confocal Imaging of Confined Quiescent and Flowing Colloid-polymer Mixtures

Published on: May 20, 2014

12.2K

Multimodal Image Registration Using a Viscous Fluid Model with the Bhattacharyya Distance.

Herng-Hua Chang

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
    |December 12, 2023
    PubMed
    Summary
    This summary is machine-generated.

    This article introduces a new 3D computer program designed to align different types of medical scans, such as MRI, to help doctors better diagnose and treat brain conditions. By using advanced fluid physics and statistical matching, the system accurately combines images without needing large datasets or long training periods.

    Keywords:
    brain MRI analysisvolumetric alignmentNavier-Stoke's equationhopscotch method

    Frequently Asked Questions

    More Related Videos

    Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
    07:13

    Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities

    Published on: October 27, 2023

    1.2K
    Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
    05:05

    Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

    Published on: November 23, 2019

    8.0K

    Related Experiment Videos

    Last Updated: Jul 8, 2025

    Confocal Imaging of Confined Quiescent and Flowing Colloid-polymer Mixtures
    10:56

    Confocal Imaging of Confined Quiescent and Flowing Colloid-polymer Mixtures

    Published on: May 20, 2014

    12.2K
    Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
    07:13

    Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities

    Published on: October 27, 2023

    1.2K
    Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
    05:05

    Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

    Published on: November 23, 2019

    8.0K

    Area of Science:

    • Medical imaging informatics and multimodal image registration techniques
    • Computational neuroscience and diagnostic image analysis

    Background:

    Medical image alignment remains a persistent challenge for clinicians needing to integrate diverse diagnostic data. Prior research has shown that monomodal techniques often fail to reconcile scans from different physical acquisition modalities. That uncertainty drove the need for robust 3D frameworks capable of handling complex volumetric data. Current approaches frequently struggle with the computational demands of high-resolution brain imaging. No prior work had resolved the trade-off between deformation accuracy and processing efficiency in fluid-based models. Existing literature highlights that standard intensity-based metrics often lack the sensitivity required for cross-modality alignment. This gap motivated the development of more sophisticated mathematical foundations for spatial normalization. Researchers continue to seek methods that provide reliable anatomical correspondence across disparate imaging protocols.

    Purpose Of The Study:

    The study aims to develop a robust 3D multimodal image registration algorithm utilizing a viscous fluid model. Researchers seek to address the limitations of existing 2D methods in interpreting volumetric medical data. The project focuses on creating a framework that effectively aligns images from different acquisition modalities. By associating the fluid model with the Bhattacharyya distance, the team intends to improve the precision of spatial normalization. This work addresses the specific need for accurate diagnostic tools that do not rely on extensive training sets. The authors aim to provide a solution that simplifies treatment planning for complex brain conditions. The investigation is motivated by the challenge of reconciling disparate intensity distributions in medical scans. Ultimately, the researchers strive to establish a reliable computational foundation for automated image processing in clinical settings.

    Main Methods:

    The review approach focuses on a novel 3D computational framework for aligning volumetric medical scans. Investigators utilize a modified Navier-Stoke's equation to govern the deformation process within the fluid-based environment. The team implements the hopscotch method to solve velocity fields across explicit and implicit grid positions. Researchers integrate the differential of the Bhattacharyya distance directly into the body force function. This specific configuration serves as the primary driver for spatial transformation between different image types. The study evaluates the proposed system using a comprehensive set of simulated and real brain MR scans. Comparisons are drawn against various competing algorithms to establish relative performance metrics. The methodology emphasizes achieving high accuracy while maintaining computational efficiency for clinical applications.

    Main Results:

    Key findings from the literature demonstrate that the proposed algorithm achieves high registration accuracy across diverse clinical scenarios. The researchers report that their system consistently outperforms competing methods in multiple multimodal tasks. Experimental data derived from simulated brain MR images confirm the robustness of the fluid-based deformation model. Real-world testing further validates the efficacy of the approach in handling complex anatomical variations. The study highlights that the integration of the Bhattacharyya distance significantly enhances the alignment of disparate imaging modalities. Quantitative assessments indicate that the hopscotch numerical solver maintains stable velocity field computations throughout the process. The authors observe that their framework functions effectively without the requirement for massive training datasets. These results suggest that the system provides a reliable alternative to existing registration techniques in medical diagnostics.

    Conclusions:

    The authors propose that their fluid-based framework offers a reliable solution for complex volumetric alignment tasks. Synthesis and implications suggest that incorporating statistical distance metrics improves the precision of cross-modality deformation. The researchers demonstrate that their specific implementation achieves superior performance compared to existing standard algorithms. This study indicates that high-fidelity registration is possible without requiring extensive training sets or massive computational overhead. The findings imply that clinical workflows could benefit from more accurate anatomical mapping during diagnostic procedures. The authors conclude that their approach effectively handles various challenging scenarios encountered in brain imaging. Their results suggest that this method provides a versatile tool for medical professionals involved in treatment planning. The team maintains that their model represents a significant advancement in automated image processing capabilities.

    The researchers utilize a modified Navier-Stoke's equation as the primary framework. By integrating the differential of the Bhattacharyya distance into the body force function, the system generates the necessary deformation field to align disparate volumetric datasets effectively.

    The hopscotch method serves as the numerical solver for the velocity field. This technique computes values at explicit locations first, followed by solving implicit positions through transposition, which ensures computational stability during the fluid simulation process.

    The authors incorporate the Bhattacharyya distance into the body force function. This statistical metric is necessary to quantify the similarity between different imaging modalities, allowing the fluid model to deform images until they reach optimal alignment.

    The body force function acts as the main driving force for deformation. It utilizes the statistical differences between images to guide the fluid movement, ensuring that the target and source volumes are correctly mapped onto one another.

    The team utilized a variety of simulated and real brain Magnetic Resonance (MR) images to validate their system. These diverse datasets allowed the researchers to assess the algorithm's accuracy across multiple challenging registration scenarios.

    The authors claim that their system facilitates disease diagnosis and treatment planning. They suggest that this tool provides accurate 3D alignment without the need for massive data or extensive training, regardless of the specific imaging modality used.