In situ Grazing Incidence Small Angle X-ray Scattering on Roll-To-Roll Coating of Organic Solar Cells with Laboratory X-ray Instrumentation
Published on: March 2, 2021
A Condensed History Approach to X-Ray Dark Field Effects in Edge Illumination Phase Contrast Simulations
Abstract:
X-ray dark field signals, measurable in many x-ray phase contrast imaging (XPCI) setups, stem from unresolvable microstructures in the scanned sample. This makes them ideally suited for the detection of certain pathologies, which correlate with changes in the microstructure of a sample. Simulations of x-ray dark field signals can aid in the design and optimization of XPCI setups, and the development of new reconstruction techniques. Current simulation tools, however, require explicit modelling of the sample microstructures according to their size and spatial distribution. This process is cumbersome, does not translate well between different samples, and considerably slows down simulations. In this work, a condensed history approach to modelling x-ray dark field effects is presented, under the assumption of an isotropic distribution of microstructures, and applied to edge illumination phase contrast simulations. It substantially simplifies the sample model, can be easily ported between samples, and is two orders of magnitude faster than conventional dark field simulations, while showing equivalent results.Clinical relevance- Dark field signal provides information on the microstructure distribution within the investigated sample, which can be applied in areas such as histology and lung x-ray imaging. Efficient simulation tools for this dark field signal aid in optimizing scanning setups, acquisition schemes and reconstruction techniques.
More Related Videos
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...