Continual Learning for Cuffless Blood Pressure Measurement using PPG and ECG Signals
Abstract:
Although numerous studies have been conducted on cuffless blood pressure (BP) estimation using machine learning methods, most of the data-driven models are static, with model parameters fixed after training is complete. However, BP is dynamic and the performance would degrade for a static model when the to-be predicted BP distribution deviates from the training BP distribution. In this paper, we propose a continual learning (CL) framework in which deep learning models are developed to learn dynamically and continuously for arterial BP (ABP) estimation with photoplethysmography (PPG) and electrocardiogram (ECG) waveforms. The effectiveness of the CL model is validated on UCI Repository and MIMIC-III database with a total of 132 individual samples, and compared with conventional training method. It was found that the CL model improved the ABP estimation accuracy in terms of mean absolute error (MAE) by 17.47% on average compared with conventional training model. Furthermore, the improvement increased with the variability of ABP. These results demonstrate that CL model has potential to estimate dynamic ABP, which has been challenging with conventional training.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement