From peripheral finger-derived pulse waveforms to aortic pressure waveform features: an application of a generalized
Objective:
Aortic (central) pressure features are associated with cardiovascular complications and can be algorithmically derived from non-invasive peripheral arterial waveforms. This has conventionally been performed with a pressure waveform (i.e., tonometry or oscillometry) rather than with the optical-based sensor (photoplethysmography (PPG)) that is predominantly used in wearable health devices. Extraction of aortic features from a peripheral PPG waveform has yet to be investigated. This study aims to compare aortic features extracted from peripheral arterial waveforms acquired with different sensor modalities using the same transfer function.
Design And Method:
Radial tonometry (reference), finger volume-clamped PPG (Peňáz) and fingertip PPG waveforms were measured in participants (n=29, 36±16 years, 15 female) under baseline conditions. Waveforms were converted into an aortic pressure waveform using the transfer function. Waveform features were extracted from the converted waveform. Extracted features were compared with correlation plots and a Bland-Altman analysis.
Results:
Aortic pressure features extracted from a finger using the Peňáz technique were comparable to radial tonometry derived features. Aortic features extracted from a fingertip waveform were more variable in comparison to radial tonometry-derived features.
Conclusions:
Aortic (central) pressure waveform features contain valuable haemodynamic information and have the capacity to be easily and conveniently implemented in wearable health devices. Future use of these features in wearable health devices incorporating PPG requires the development, and/or, optimization of a unique transfer function to more accurately represent the aortic pressure waveform for cardiovascular assessment.Clinical Relevance- Aortic pressure features might be used in wearable health devices following the development of a unique transfer function for optical-transduced peripheral vascular signals.
Related Concept Videos
Pulse
The pulse serves as a clinical...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Rectangular and Triangular Pulse Function
For example, consider a rectangular pulse with a 5V amplitude, a 3-second duration, and centered at t=2 seconds. This pulse can be expressed using the rectangular function, written as,