Related Experiment Video
Updated: Jul 8, 2025

Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Plethysmograph-Based Self-Assessment Device for Carotid-Femoral Pulse Wave Velocity Measurement: A Pilot Usability
Abstract:
Arterial stiffness, a proxy of vascular aging is an important marker of cardiovascular events and mortality, independent of traditional risk factors. The aortic or carotid-femoral pulse wave velocity (cf-PWV) is the gold standard for determining arterial stiffness. Measuring arterial stiffness can help identify people who are at risk early on. State-of-the-art devices, majorly employing applanation tonometry at the carotid site, demand extensive skill, are costly, and are not intended for out-of-clinic use. However, a device that is suitable for homecare and primary health settings would facilitate primordial care. To address this gap, we have developed a novel easy-to-use, fully automated, and affordable photoplethysmography-based device for measuring cf-PWV. An in-vivo study on 25 subjects was conducted to investigate the device's usability by comparing self and expert-performed measurements, and by quantifying the user experience (score out of 5). A strong correlation (r = 0.88) and a statistically insignificant bias indicated the measurement reproducibility in self-versus expert-performed measurements. An average usability score of 3.98 ± 0.83 given by the participants showed the convenience and ease of use of the device. The results demonstrate the feasibility and reliability of using the device by inexperienced operators, even when newly introduced. Future clinical studies are in progress to assess the device's accuracy in comparison to gold-standard reference equipment.Clinical Relevance-This pilot study revealed the device's potential to offer a user-friendly solution for home care and other non-hospital settings.
Related Concept Videos
Pulse Assessment Sites
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...

