Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
Photoplethysmography-based derivation of physiological information using the BioPoint
Abstract:
The BioPoint is a new wireless and wearable device, targeting both the ambulatory and on-site monitoring of biosignals. It is described as being capable of streaming and recording the i) electromyography, ii) electrocardiography, iii) electrodermal activity, iv) photoplethysmography, v) skin temperature and vi) actigraphy simultaneously, while making the raw signals recorded by the sensors readily available. However, an in-depth assessment of the biophysical signals recorded by this device, as well as its ability to derive vital signs and other health metrics, remains to be carried out. Consequently, this work proposes a preliminary study to evaluate the quality of the signals that can be acquired by this wearable with a focus on the derivation of heart rate and peripheral blood oxygenation via photoplethysmography. The device is quantitatively compared to the medical-grade pulse oximeter NoninConnect 3245, by Nonin inc. This study was performed with participants wearing the BioPoint at different positions on the body (finger, wrist, forearm, biceps and plantar arch), while the NoninConnect was worn on the fingertip and used as the ground truth. The results show that the BioPoint can accurately determine both heart rate and oxygen saturation from various locations on the body. However, as the BioPoint's photoplethysmograph is not calibrated it cannot be used for medical purposes (non-medical-grade).
More Related Videos
08:22Author Spotlight: Advancing the Study of Brain-Heart Interplay with a Comprehensive EEGLAB Plugin for Multimodal Signal Analysis
Published on: April 26, 2024
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement