Reducing the need for repeating urine drug testing with the gray zone determined by the measurement uncertainty

Kagan Huysal1, Yasemin Üstündağ1, Hatice Azra Çağlak1

  • 1University of Health Sciences, Bursa Yüksek Ihtisas Training and Research Hospital, Department of Clinical Biochemistry, Bursa, Turkey.

PubMed
Abstract

Related Concept Videos

Determination of Renal Drug Clearance: Graphical and Midpoint Methods01:07

Determination of Renal Drug Clearance: Graphical and Midpoint Methods

Renal clearance, a crucial parameter in pharmacokinetics, can be determined using two different methods: the graphical method and the midpoint method. These methods provide insights into the rate of drug excretion by the kidneys and aid in assessing renal function.
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
128
One-Compartment Open Model: Urinary Excretion Data and Determination of k01:11

One-Compartment Open Model: Urinary Excretion Data and Determination of k

The one-compartment open model leverages urinary excretion data to estimate renal clearance, which gauges the kidney's capacity to expel a drug. This method offers several benefits, including directly measuring drug elimination and assessing the kidney's contribution to overall drug clearance. However, this approach has limitations. It assumes sole renal excretion of the drug, which is not true for all drugs. Accurate urinary excretion and plasma drug concentration measurement can also...
185
Factors Affecting Renal Clearance: Renal Impairment01:17

Factors Affecting Renal Clearance: Renal Impairment

Renal dysfunction significantly impairs the renal clearance of drugs, leading to potential complications in drug therapy. Renal failure, which can be caused by various factors, poses a significant challenge in the elimination of drugs from the body.
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
98
Data Validation01:15

Data Validation

Method validation is a crucial process in analytical chemistry designed to confirm that a given method consistently produces reliable and high-quality results. This process is essential when a method is applied to different sample matrices or when procedural modifications are made, ensuring that the results meet acceptable standards across various applications.
Key parameters for method validation include:
164
Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. 
73.7K