Related Experiment Video
Updated: Jul 8, 2025

Development of a Virtual Reality Assessment of Everyday Living Skills
Published on: April 23, 2014
Non-standard diagnostic assessment reliability in psychiatry: a study in a Brazilian outpatient setting using Kappa
Helio G Rocha Neto1,2, José Luiz Martins Lessa3, Luisa Mendez Koiller3
1Programa de Pós-Graduação em Psiquiatria e Saúde Mental - PROPSAM, Instituto de Psiquiatria da UFRJ, Av.Venceslau Brás, nº71 Fundos, Gabinete da Direção, Botafogo, Rio de Janeiro, RJ, Brazil. helio.neto@edu.ulisboa.pt.
Abstract:
The use of Structured Diagnostic Assessments (SDAs) is a solution for unreliability in psychiatry and the gold standard for diagnosis. However, except for studies between the 50 s and 70 s, reliability without the use of Non-SDAs (NSDA) is seldom tested, especially in non-Western, Educated, Industrialized, Rich, and Democratic (WEIRD) countries. We aim to measure reliability between examiners with NSDAs for psychiatric disorders. We compared diagnostic agreement after clinician change, in an outpatient academic setting. We used inter-rater Kappa measuring 8 diagnostic groups: Depression (DD: F32, F33), Anxiety Related Disorders (ARD: F40-F49, F50-F59), Personality Disorders (PD: F60-F69), Bipolar Disorder (BD: F30, F31, F34.0, F38.1), Organic Mental Disorders (Org: F00-F09), Neurodevelopment Disorders (ND: F70-F99) and Schizophrenia Spectrum Disorders (SSD: F20-F29). Cohen's Kappa measured agreement between groups, and Baphkar's test assessed if any diagnostic group have a higher tendency to change after a new diagnostic assessment. We analyzed 739 reevaluation pairs, from 99 subjects who attended IPUB's outpatient clinic. Overall inter-rater Kappa was moderate, and none of the groups had a different tendency to change. NSDA evaluation was moderately reliable, but the lack of some prevalent hypothesis inside the pairs raised concerns about NSDA sensitivity to some diagnoses. Diagnostic momentum bias (that is, a tendency to keep the last diagnosis observed) may have inflated the observed agreement. This research was approved by IPUB's ethical committee, registered under the CAAE33603220.1.0000.5263, and the UTN-U1111-1260-1212.
Related Concept Videos
Kendall's Coefficient of Concordance
Kendall's Tau Test
A τ value...
Receiver Operating Characteristic Plot
Reliability and Validity
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...

