Related Experiment Video
Updated: Jul 8, 2025

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Short-term clinical results of bicruciate-retaining total knee arthroplasty using personalized alignment
Hiroshi Inui1,2, Ryota Yamagami3, Kenichi Kono3
1Saitama Medical Center, Saitama Medical University, 1981 Kamoda, Kawagoe City, Saitama, 350-8500, Japan. hiroshi_inu0707@yahoo.co.jp.
Background:
Bicruciate-retaining (BCR) prosthesis has been introduced to recreate normal knee movement by preserving both the anterior and posterior cruciate ligaments. However, the use of BCR total knee arthroplasty (TKA) is still debatable because of several disappointing reports. We have been performing BCR TKAs with personalized alignment (PA). This study aimed to reveal the limb alignment and soft tissue balance of FA-BCR TKAs and compare the clinical outcomes of FA-BCR TKAs with those of unicompartmental knee arthroplasty (UKA).
Methods:
Fifty BCR TKAs and 58 UKAs were included in this study. The joint component gaps of BCR TKA were evaluated intraoperatively and the postoperative hip-knee-ankle (HKA) angle, medial proximal tibial angle (MPTA), and lateral distal femoral angle (LDFA) were measured using full-length standing radiography. The short-term clinical outcomes of BCR TKAs were compared with those of UKA using the scoring system of 2011 Knee Society Scoring (KSS) and the knee injury and osteoarthritis outcome score (KOOS) at an average of 2 years postoperatively (1-4yeras).
Results:
The coronal alignment values of PA-BCR TKA were as follows: HKA angle, 177.9° ± 2.3°; MPTA, 85.4° ± 1.9°; and LDFA, 87.5° ± 1.9°. The joint component gaps at flexion angles of 10°, 30°, 60°, and 90° were 11.1 ± 1.2, 10.9 ± 1.4, 10.7 ± 1.3, and 11.2 ± 1.4 mm for the medial compartment and 12.9 ± 1.5, 12.6 ± 1.8, 12.5 ± 1.8 and 12.5 ± 1.7 mm for the lateral compartment, respectively. The patient expectation score and maximum extension angle of PA-BCR TKA were significantly better than those of UKAs.
Conclusions:
The short-term clinical outcomes of PA-BCR TKA were comparable or a slightly superior to those of UKAs.
More Related Videos
07:33In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022