Related Experiment Video
Updated: Jul 8, 2025

Author Spotlight: Revolutionizing Remote Surgery with Augmented Reality and Robotics for Enhanced Precision and Accessibility
Published on: August 9, 2024
Daily Physical Activity Measured by Wearable Smartwatch for Patients Undergoing Transcatheter Aortic Valve
Jiaqi Fan1,2,3, Qiong Liu1,3,4, Hanyi Dai5
1Department of Cardiology (J.F., Q.L., Y.G., L.W., P.H., J.J., X. Lin, X. Liu, J.W.), Second Affiliated Hospital Zhejiang University School of Medicine, Hangzhou, China.
Background:
This study aims to evaluate limited data about daily physical activity patterns, influential factors, and their association with 1-year mortality or rehospitalization after transcatheter aortic valve replacement (TAVR) through smartwatches.
Methods:
Consecutive severe aortic stenosis patients undergoing elective transfemoral TAVR in a Chinese tertiary hospital were enrolled from July 2021 to May 2022 and received a Huawei smartwatch at least 1 day before TAVR. The primary outcome was a composite of all-cause mortality or hospital readmission within 1 year. Linear mixed-effects models were applied to determine influential factors of daily step counts, and Cox proportional hazard regression models were to estimate the association between baseline step counts within 1 month since discharge and composite outcome from months 2 to 12. The dose-response association was assessed using restricted cubic spline curves.
Results:
A total of 222 participants and 59 469 valid monitoring person-day records were included (mean age, 72.7 years; 61% women). Step counts increased rapidly within the first 2 months (P<0.001), followed by a slower increase for those without composite outcomes (P=0.029) and a gradual decrease for those who developed composite outcomes (P<0.001). In multivariate linear mixed models, a 1-m increase in baseline 6-minute walk test and a 1-month delay after discharge were associated with 4 (95% CI, 1-7) and 170 (95% CI, 145-194) additional step counts, respectively. In restricted cubic spline analysis, the hazard ratio declined progressively until ≈5000 steps per day, after which they leveled. Below 5000 steps, the adjusted hazard ratio of composite outcome associated with each 1000-step count increase was 0.67 (0.50-0.89; P=0.007). However, above 5000 steps, step counts were not significantly associated with the composite outcome (P=0.645), with a hazard ratio of 1.12 (0.70-1.79).
Conclusions:
Daily step counts rapidly increased within the first 2 months post-TAVR. Increased physical activity was associated with a lower risk of 1-year mortality or rehospitalization after TAVR for patients with daily step counts below 5000.
Registration:
URL: https://www.clinicaltrials.gov; Unique identifier: NCT04454177.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes