A multicenter study of modified electron beam output calibration.
Dwi Aprilia Mahfirotin1,2, Brian Ferliano3, Andrian Dede Handika4
1Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok, West Java, Indonesia.
A modified electron beam calibration shows comparable accuracy to established protocols (IAEA TRS-398, AAPM-TG-51) in multicenter radiotherapy. This suggests current protocols need updates for linac component stability in electron beam calibration.
Area of Science:
- Medical Physics
- Radiotherapy Dosimetry
- Radiation Oncology
Background:
- Accurate electron beam calibration is crucial for effective radiotherapy.
- Existing protocols like IAEA TRS-398 and AAPM-TG-51 are widely used but may require updates.
- Multicenter studies are essential to assess the generalizability of calibration procedures.
Purpose of the Study:
- To evaluate the accuracy of a modified electron beam calibration procedure.
- To compare the modified calibration against established protocols (IAEA TRS-398 and AAPM-TG-51).
- To assess the performance of the modified calibration across multiple radiotherapy institutions.
Main Methods:
- Utilized Elekta and Varian Linear Accelerators with electron beam energies from 4-22 MeV.
- Employed both cylindrical and parallel-plate ionization chambers for dosimetry measurements.
- Developed a modified calibration using a cylindrical chamber and updated data derived from Monte Carlo calculations.
Main Results:
- The modified calibration demonstrated beam quality conversion factors comparable to TRS-398 and TG-51.
- Dose ratios between the modified calibration and TRS-398/TG-51 showed variations within acceptable clinical ranges.
- The study confirmed the feasibility of the modified calibration across different institutions and equipment.
Conclusions:
- The modified electron beam calibration procedure is accurate and reliable for multicenter radiotherapy.
- Findings support the need to update current calibration protocols with more detailed metrics.
- Emphasis on linac component stability is recommended for future dosimetry protocols.