A comparative study of energy graph-based fault detection and isolation techniques applied to a lignite plant
Jan Hendrik Smith1, George van Schoor2, Kenneth R Uren1
1School of Electrical, Electronic and Computer Engineering, Faculty of Engineering, North-West University, South Africa.
Abstract:
Energy and exergy interactions in industrial systems hold meaning across physical domains. This paper builds on the notion that capturing the energy and exergy interactions of a system, while retaining physical structural context, enables fault detection and isolation. To this end, three energy graph-based visualisation methods were developed for the purpose of fault detection and isolation. This paper presents a comparative study of the three analysis methods designated the 1) distance parameter method, 2) eigenvalue decomposition method, and 3) residual method. The study utilises data from a physical lignite plant in Janschwalde, Germany, in combination with simulation data of specific faults in order to compare the sensitivity and robustness of the three methods. The comparison is done firstly in terms of detection and secondly in terms of isolation. The distance parameter and eigenvalue decomposition methods showed high sensitivity and robustness for fault detection, while the residual method showed moderate comparative performance. In terms of fault isolation, the distance parameter method showed high sensitivity and robustness, while the eigenvalue decomposition method had irregular isolation performance. The residual method isolation results proved inconclusive.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
Related Concept Videos
Fault Types
For line-to-line faults occurring between phases B and C, the...
Power System Three-Phase Short Circuits
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Differential Relays