Purpose:
SABR is increasingly used to treat renal cell carcinoma (RCC). However, the optimal method to assess treatment response is unclear. We aimed to quantify changes in both volume and maximum linear size of tumors after SABR and evaluate the utility of the 2 approaches in treatment response assessment.
Methods And Materials:
We retrospectively studied patients with RCC treated with SABR at our institution between 2013 and 2020. All available follow-up computed tomography scans were aligned, and tumors were contoured on all scans. Volume and maximum linear size were measured at each follow-up, relative to these measurements at the time of computed tomography simulation.
Results:
Twenty-four patients with 25 tumors were included. Median follow-up was 32 months (range, 16-67). Nineteen tumors (76%) had 30% volumetric response at a median time of 7 months after SABR, and 12 tumors (48%) had 30% decrease in maximum linear size at a median time of 16 months. Eighteen tumors (72%) decreased in volume on first follow-up scan and continued to shrink, and 5 tumors (20%) displayed transient growth after SABR (average 24% increase in volume). Compared with T1a tumors, T1b or larger tumors were more likely to have transient growth (8% vs 33%; P = .16) and had higher average relative volume 24 months after SABR (0.47 vs 0.8; P = .022).
Conclusions:
Volume measurement results in more pronounced and earlier change compared with linear size measurement when assessing response to SABR. These findings may provide guidance when assessing treatment response for patients with RCC treated with SABR.
More Related Videos
09:31In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
Published on: March 30, 2015
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration