Related Experiment Video
Updated: Jul 8, 2025

A Postoperative Evaluation Guideline for Computer-Assisted Reconstruction of the Mandible
Published on: January 28, 2020
Correlation Between Presurgical Alveolar Cleft Volume Measured by Simulation Software Using CBCT and Actual Bone
Poomsthira Jotikasthira1, Marasri Chaiworawitkul1, Krit Khwanngern2
1Department of Orthodontic and Pediatric Dentistry, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand.
Abstract:
ObjectiveTo assess correlation between presurgical alveolar cleft volume measured by simulation software using CBCT and actual bone volume used for grafting.DesignProspective.SettingUniversity hospital.PatientsPatients with UCCLP who underwent alveolar bone grafting.Interventions23 CBCT images of patients with UCCLP, aged 8.6-22.9 years, were taken. Alveolar cleft volume was measured using Mimics® software. Paired t-test was used to compare volume calculated from two measuring methods. Independent t-test was used to compare the volume between two age groups. Pearson's correlation coefficient was used to assess correlation between two measuring methods.Main Outcome MeasuresPaired t-test showed statistically significant difference between two measuring methods. Independent t-test showed statistically significant difference between both measuring methods in both age groups. Differences between two variables in both age groups were not significantly different. Pearson's correlation coefficient indicated significantly positive correlation between presurgical alveolar cleft volume measured by simulation software using CBCT and actual bone volume used for grafting.ResultsMean alveolar cleft volume measured by computer simulation was 1.30 ± 0.40 ml, whereas actual bone volume used for grafting was 1.10 ± 0.39 ml. Mean difference between both measuring methods was 0.20 ± 0.14 ml. Mean alveolar cleft volume measured by simulation software, as well as actual bone volume used for grafting, differ significantly between 2 age groups.ConclusionsThere was significantly positive correlation between two measuring methods. CBCT method overestimated actual bone graft volume. Surgeons may harvest alveolar bone grafts ranging from 82% to 100% of CBCT volume.
More Related Videos
09:10Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures
Published on: August 5, 2021
13:16Computed Tomography and Optical Imaging of Osteogenesis-angiogenesis Coupling to Assess Integration of Cranial Bone Autografts and Allografts
Published on: December 22, 2015