Related Experiment Video
Updated: Jul 8, 2025

Standardized Method for Measuring Collection Efficiency from Wipe-sampling of Trace Explosives
Published on: April 10, 2017
[Current approaches for sampling to study the traces of gunshot residue]
A V Oberenko1,2, S A Sagalakov1, S V Kachin1
1Siberian Federal University, Krasnoyarsk, Russia.
Abstract:
An overview of researches, mainly by foreign specialists, on current available approaches for sampling to study the traces of gunshot residue (GSR) is presented. The comparative characteristics of traditional methods of samples (use of cotton and gauze tampons, blotting paper, textile fabrics, adhesive tapes, adhesives and vacuum samplers), as well as advanced technologies, including special devices and sorbents, are given. The characteristics of samplings from hands, scalp, nostrils, clothes of examined persons as well as procedures, that allow to increase the duration of GSR detection, are described in details. The importance of GSR sustainability over time is noted. On average, the most likely detection periods of particles are less than 1 hour for samples, collected from hands, more than 1 hour for samples from clothes and 2-3 hours for face. It is possible to detect the GSR particles in hair up to 24 h., and in nasal mucus after 6 h. of shot. The methods of identification and determination for analytes of inorganic and organic nature are discussed. The most common methods for determining heavy metal particles are atomic spectrometry, namely atomic absorption with electrothermal atomization and atomic emission. The combination of scanning laser ablation and mass-spectrometry with inductively coupled plasma makes it possible to detect more than 15 analytes in a single sample. Scanning electron microscopy with X-ray detectors is effective for the examination of powder particles. The described methods of sampling complement each other increasing the possibility of evidence base for court proceedings.
More Related Videos
07:09Preparation and Application of a New Bacterial Biosensor for the Presumptive Detection of Gunshot Residue
Published on: May 9, 2019
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Atomic Absorption Spectroscopy: Atomization Methods