Purpose:
The aim of this study was development and evaluation of a fully automated tool for the detection and segmentation of mPCa lesions in whole-body [68Ga]Ga-PSMA-11 PET scans by using a nnU-Net framework.
Methods:
In this multicenter study, a cohort of 412 patients from three different center with all indication of PCa who underwent [68Ga]Ga-PSMA-11 PET/CT were enrolled. Two hundred cases of center 1 dataset were used for training the model. A fully 3D convolutional neural network (CNN) is proposed which is based on the self-configuring nnU-Net framework. A subset of center 1 dataset and cases of center 2 and center 3 were used for testing of model. The performance of the segmentation pipeline that was developed was evaluated by comparing the fully automatic segmentation mask with the manual segmentation of the corresponding internal and external test sets in three levels including patient-level scan classification, lesion-level detection, and voxel-level segmentation. In addition, for comparison of PET-derived quantitative biomarkers between automated and manual segmentation, whole-body PSMA tumor volume (PSMA-TV) and total lesions PSMA uptake (TL-PSMA) were calculated.
Results:
In terms of patient-level classification, the model achieved an accuracy of 83%, sensitivity of 92%, PPV of 77%, and NPV of 91% for the internal testing set. For lesion-level detection, the model achieved an accuracy of 87-94%, sensitivity of 88-95%, PPV of 98-100%, and F1-score of 93-97% for all testing sets. For voxel-level segmentation, the automated method achieved average values of 65-70% for DSC, 72-79% for PPV, 53-58% for IoU, and 62-73% for sensitivity in all testing sets. In the evaluation of volumetric parameters, there was a strong correlation between the manual and automated measurements of PSMA-TV and TL-PSMA for all centers.
Conclusions:
The deep learning networks presented here offer promising solutions for automatically segmenting malignant lesions in prostate cancer patients using [68Ga]Ga-PSMA PET. These networks achieve a high level of accuracy in whole-body segmentation, as measured by the DSC and PPV at the voxel level. The resulting segmentations can be used for extraction of PET-derived quantitative biomarkers and utilized for treatment response assessment and radiomic studies.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET