Related Experiment Video
Updated: Jul 8, 2025

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
A new tidal breathing measurement device detects bronchial obstruction during methacholine challenge test
Andreas Zachariades1, Nadav Bachar2, Noy Danino2
1Nicosia Lung Center, Nicosia, Cyprus.
Purpose:
Bronchial hyperresponsiveness (BHR), a hallmark of bronchial asthma, is typically diagnosed through a methacholine inhalation test followed by spirometry, known as the methacholine challenge test (MCT). While spirometry relies on proper patients' cooperation and precise execution of forced breathing maneuvers, we conducted a comparative analysis with the portable nanomaterial-based sensing device, SenseGuard™, to non-intrusively assess tidal breathing parameters.
Materials And Methods:
In this prospective study, 37 adult participants with suspected asthma underwent sequential spirometry and SenseGuard™ measurements after inhaling increasing methacholine doses.
Results:
Among the 37 participants, 18 were MCT responders, 17 were non-responders and 2 were excluded due to uninterpretable data. The MCT responders exhibited a significant lung function difference when comparing the change from baseline to maximum response. This was evident through a notable decrease in forced expiratory volume in 1 s (FEV1) levels in spirometry, as well as in prominent changes in tidal breathing parameters as assessed by SenseGuard™, including the expiratory pause time (Trest) to total breath time (Ttot) ratio, and the expiratory time (Tex) to Ttot ratio. Notably, the ratios Trest/Ttot (∗p = 0.02), Tex/Ttot (∗p = 0.002), and inspiratory time (Tin) to Tex (∗p = 0.04) identified MCT responders distinctly, corresponding to spirometry (∗p < 0.0001).
Conclusions:
This study demonstrates that tidal breathing assessment using SenseGuard™ device reliably detects clinically relevant changes of respiratory parameter during the MCT. It effectively distinguishes between responders and non-responders, with strong agreement to conventional spirometry-measured FEV1. This technology holds promise for monitoring clinical respiratory changes in bronchial asthma patients pending further studies.
Related Concept Videos
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...