Related Experiment Video
Updated: Jul 8, 2025

Evaluation of Colorectal Cancer Risk and Prevalence by Stool DNA Integrity Detection
Published on: June 8, 2020
Post-colonoscopy colorectal cancers in a national fecal immunochemical test-based colorectal cancer screening program
Pieter H A Wisse1, Sybrand Y de Boer2, Marco Oudkerk Pool2
1Gastroenterology and Hepatology, Erasmus MC, Rotterdam, Netherlands.
Background:
Post-colonoscopy colorectal cancers (PCCRCs) decrease the effect of colorectal cancer (CRC) screening programs. To enable PCCRC incidence reduction in the long-term, we classified PCCRCs diagnosed after colonoscopies performed in a fecal immunochemical test (FIT)-based screening program.
Methods:
PCCRCs diagnosed after colonoscopies performed between 2014-2016 for a positive FIT in the Dutch CRC screening program were included. PCCRCs were categorized according to the World Endoscopy Organization consensus statement into (a) interval PCCRC (diagnosed before the recommended surveillance); (b) non-interval type A (diagnosed at the recommended surveillance interval); (c) non-interval type B (diagnosed after the recommended surveillance interval); or (d) non-interval type C (diagnosed after the intended recommended surveillance interval, with surveillance not implemented owing to co-morbidity). The most probable etiology was determined by root-cause analysis. Tumor stage distributions were compared between categories.
Results:
116362 colonoscopies were performed after a positive FIT with 9978 screen-detected CRCs. During follow-up, 432 PCCRCs were diagnosed. The 3-year PCCRC rate was 2.7%. PCCRCs were categorized as interval (53.5%), non-interval type A (14.6%), non-interval type B (30.6%), and non-interval type C (1.4%). The most common etiology for interval PCCRCs was possible missed lesion with adequate examination (73.6%); they were more often diagnosed at an advanced stage (stage III/IV; 53.2%) compared with non-interval type A (15.9%; P<0.001) and non-interval type B (40.9%; P=0.03) PCCRCs.
Conclusions:
The 3-year PCCRC rate was low in this FIT-based CRC screening program. Approximately half of PCCRCs were interval PCCRCs. These were mostly caused by missed lesions and were diagnosed at a more advanced stage. This emphasizes the importance of high quality colonoscopy with optimal polyp detection.
More Related Videos
Related Concept Videos
Serum Laboratory Studies, Stool Test, Breath Test
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy