Related Experiment Video
Updated: Jul 20, 2026

An In Vitro Organ Culture Model of the Murine Intervertebral Disc
Published on: April 11, 2017
Comparison of the effects of different artificial discs on hybrid surgery: A finite element analysis
Wei Jiang1, Fulin Zhao1, Waseem Ur Rahman1
1School of Mechanical Engineering, Dalian University of Technology, Dalian, China.
Abstract:
In recent years, artificial cervical discs have been used in intervertebral disc replacement surgery and hybrid surgery (HS). The advantages and disadvantages of different artificial cervical discs in artificial cervical disc replacement surgery have been compared. However, few scholars have studied the biomechanical effects of various artificial disc prostheses on the human cervical spine in HS which include the Anterior Cervical Discectomy and Fusion (ACDF) and Cervical Disc Arthroplasty (CDA). This study compared the biomechanical behavior of Mobi-C and Prestige LP in the operative and adjacent segments during two-level hybrid surgery. A three-dimensional finite element model of C2-C7 was first established and validated. Subsequently, clinical surgery was then simulated to establish a surgical model of anterior cervical fusion at the C4-C5 level. Mobi-C and Prestige-LP artificial disc prostheses were implanted at the C5-C6 level to create two hybrid models. All finite element models were fixed on the lower endplate of the C7 vertebra and subjected to a load of 73.6 N and different directions of 1 Nm torque on the odontoid process of the C2 vertebra to simulate human flexion, extension, lateral bending, and axial rotation. This paper compares the ROM, intervertebral pressure, and facet joint force after hybrid surgery with the intact model. The results show that compared with Prestige LP, Mobi-C can improve ROM of the replacement segment and compensate for the intervertebral pressure of the adjacent segment more effectively, but the facet joint pressure of the replacement segment may be higher.
More Related Videos
03:24Author Spotlight: Development and Application of a Novel Suture Technique for Annular Fibrosus Repair in Percutaneous Transforaminal Endoscopic Discectomy
Published on: January 26, 2024
10:24Uniportal Full Endoscopic Posterolateral Transforaminal Lumbar Interbody Fusion
Published on: June 6, 2025
Related Concept Videos
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...