Related Experiment Video
Updated: Jul 8, 2025

A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
Published on: April 21, 2023
Comparison of the accuracy of Japanese synonym identifications using word embeddings in the radiological technology
Ayako Yagahara1, Noriya Yokohama2
1Faculty of Health Sciences, Hokkaido University of Science, 7-Jo 15-4-1 Maeda, Teine, Sapporo, Hokkaido, 006-8585, Japan. yagahara-a@hus.ac.jp.
Abstract:
The terminology in radiological technology is crucial, encompassing a broad range of principles from radiation to medical imaging, and involving various specialists. This study aimed to evaluate the accuracy of automatic synonym detection considering the characteristics of the Japanese language by Word2vec and fastText in the radiological technology field for the terminology elaboration. We collected around 340 thousand abstracts in Japanese. First, preprocessing of the abstract data was performed. Then, training models were created with Word2vec and fastText with different architectures: continuous bag-of-words (CBOW) and skip-gram, and vector sizes. Baseline synonym sets were curated by two experts, utilizing terminology resources specific to radiological technology. A term in the dataset input into the generated models, and the top-10 synonym candidates which had high cosine similarities were obtained. Subsequently, precision, recall, F1-score, and accuracy for each model were calculated. The fastText model with CBOW at 300 dimensions was most precise in synonym detection, excelling in cases with shared n-grams. Conversely, fastText with skip-gram and Word2vec were favored for synonyms without common n-grams. In radiological technology, where n-grams are prevalent, fastText with CBOW proved advantageous, while in informatics, characterized by abbreviations and transliterations, Word2vec with CBOW was more effective.
Related Concept Videos
Improving Translational Accuracy
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
X-ray Imaging
Accuracy and Precision
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...

