The Process of Sterilizing Tattoo Inks Releases Formaldehyde
Seung Hee Lee1, Myoungjin Kim2, Seongnam Kim2
1Medical Engineering Research Center, The Standard Co. Ltd., Gunpo-si, Republic of Korea, rnd2@thestd.co.kr.
Introduction:
Around 12% of Europeans and 20% of Americans have at least one tattoo. Tattoo inks, the substances used to create tattoos on the body, consist of chemicals that contain formaldehyde, which can be harmful to human health. The amount of formaldehyde present in commercially available tattoo inks and its causes are not well understood.
Methods:
We investigated the levels of formaldehyde in tattoo ink products sold in different countries and identified the factors contributing to its production. We also explored methods to reduce formaldehyde generation in tattoo inks. Seven tattoo inks from various brands were tested.
Results:
Formaldehyde release was predominantly associated with gamma radiation sterilization. Formaldehyde levels were observed to be higher in compositions containing organic components compared to those with inorganic components, irrespective of sterilization method and container type. Glycerin released over seven times more formaldehyde than other components during gamma-ray sterilization.
Conclusion:
The results suggest that the presence of hydroxyl groups in carbon organic compounds in tattoo ink leads to photodegradation during gamma-ray radiation sterilization, resulting in increased concentrations of formaldehyde. Further research is needed to examine the chemical reactions occurring during sterilization processes and identify alternative sterilization methods that minimize formaldehyde formation. Additionally, the development of tattoo inks with reduced formaldehyde content and the establishment of strict quality control measures can help ensure the safety of tattooing practices.
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...