Background:
As the global burden of hypertension continues to increase, early diagnosis and treatment play an increasingly important role in improving the prognosis of patients. In this study, we developed and evaluated a method for predicting abnormally high blood pressure (HBP) from infrared (upper body) remote thermograms using a deep learning (DL) model.
Methods:
The data used in this cross-sectional study were drawn from a coronavirus disease 2019 (COVID-19) pilot cohort study comprising data from 252 volunteers recruited from 22 July to 4 September 2020. Original video files were cropped at 5 frame intervals to 3,800 frames per slice. Blood pressure (BP) information was measured using a Welch Allyn 71WT monitor prior to infrared imaging, and an abnormal increase in BP was defined as a systolic blood pressure (SBP) ≥140 mmHg and/or diastolic blood pressure (DBP) ≥90 mmHg. The PanycNet DL model was developed using a deep neural network to predict abnormal BP based on infrared thermograms.
Results:
A total of 252 participants were included, of which 62.70% were male and 37.30% were female. The rate of abnormally high HBP was 29.20% of the total number. In the validation group (upper body), precision, recall, and area under the receiver operating characteristic curve (AUC) values were 0.930, 0.930, and 0.983 [95% confidence interval (CI): 0.904-1.000], respectively, and the head showed the strongest predictive ability with an AUC of 0.868 (95% CI: 0.603-0.994).
Conclusions:
This is the first technique that can perform screening for hypertension without contact using existing equipment and data. It is anticipated that this technique will be suitable for mass screening of the population for abnormal BP in public places and home BP monitoring.
Related Concept Videos
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Measurement of Blood Pressure