Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Experimental Evaluation of a 3-D CZT Imaging Spectrometer for Potential Use in Compton-Enhanced PET Imaging
Yifei Jin1, Michael Streicher2, Hao Yang2
1Department of Nuclear, Plasma and Radiological Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA.
Abstract:
We constructed a prototype positron emission tomography (PET) system and experimentally evaluated large-volume 3-D cadmium zinc telluride (CZT) detectors for potential use in Compton-enhanced PET imaging. The CZT spectrometer offers sub-0.5-mm spatial resolution, an ultrahigh energy resolution (~1% @ 511 keV), and the capability of detecting multiple gamma-ray interactions that simultaneously occurred. The system consists of four CZT detector panels with a detection area of around 4.4 cm × 4.4 cm. The distance between the front surfaces of the two opposite CZT detector panels is ~80 mm. This system allows us to detect coincident annihilation photons and Compton interactions inside the detectors and then, exploit Compton kinematics to predict the first Compton interaction site and reject chance coincidences. We have developed a numerical integration technique to model the near-field Compton response that incorporates Doppler broadening, detector's finite resolutions, and the distance between the first and second interactions. This method was used to effectively reject random and scattered coincidence events. In the preliminary imaging studies, we have used point sources, line sources, a custom-designed resolution phantom, and a commercial image quality (IQ) phantom to demonstrate an imaging resolution of approximately 0.75 mm in PET images, and Compton-based enhancement.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET