Study Objective:
To identify Change in Systemic Arterial Pulsatitlity index (ΔSAPi) as a novel hemodynamic marker associated with outcomes in heart failure (HF).
Design:
The ESCAPE trial was a randomized controlled trial.
Setting:
The ESCAPE trial was conducted at 26 sites.
Participants:
134 patients were analyzed (mean age 56.8 ± 13.4 years, 29% female).
Interventions:
We evaluated the change in SAPi, ([systemic pulse pressure/pulmonary artery wedge pressure) obtained at baseline and at the final hemodynamic measurement in the ESCAPE trial.
Main Outcome Measures:
Change in SAPi, (ΔSAPi), was analyzed for the primary outcomes of death, heart transplant, left ventricular assist device (DTxLVAD) or hospitalization, (DTxLVADHF) and secondary outcome of DTxLVAD using Cox proportional hazards regression.
Results:
Median change in SAPi was 0.81 (IQR 0.20-1.68). ΔSAPi in uppermost quartile was associated with reductions in DTxLVADHF (HR 0.55 [95% CI 0.32, 0.93]). ΔSAPi in the uppermost and lowermost quartiles combined was similarly associated with significant reductions in DTxLVADHF (HR 0.62 [95% CI 0.41, 0.94]). ΔSAPi higher than 1.17 was associated with improved DTxLVADHF. ΔSAPi was also associated with troponin levels at discharge (regression coefficient p = 0.001) and trended with 6-minute walk at discharge (Spearman correlation r = 0.179, p = 0.058).
Conclusion:
ΔSAPi was strongly associated with improved HF clinical profile and adverse outcomes. These findings support further exploration of Δ SAPi in the risk stratification of HF.
More Related Videos
08:12Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
08:42Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Related Concept Videos
Pulse
The pulse serves as a clinical...
Measurement of Blood Pressure
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Pathophysiology of Heart Failure
Blood Pressure
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...