Related Experiment Video
Updated: Jul 23, 2026

Development of a Virtual Reality Assessment of Everyday Living Skills
Published on: April 23, 2014
A Comparative Assessment of Acceptance of Different Types of Functional Appliances
Anju Jha1, Richa Shree2, Sovendu Jha2
1Department of Pediatric and Preventive Dentistry, Patna Dental College and Hospital, Patna, IND.
Abstract:
Background Modern clinical orthodontics' functional appliances, a well-established modality of treatment, exhibit an amazing diversity of design. Clinical findings show that people have difficulty adjusting to these devices due to their size and unfixed positioning inside the mouth and that patient adaptation may vary based on the type of orthodontic functional appliance employed. Despite the fact that they appear to inflict more pain and soreness than, for example, removable plates, the effects of various orthodontic functional appliances on patients' acclimation have not yet been researched. Aim The current study's goal was to assess how different functional appliances' shapes and designs affected patients' willingness to accept them. Materials and methods About 20 adult volunteers (10 males and 10 females, age 18-32 years) with marked Class II division 1 malocclusion and not familiar with orthodontic appliances were selected as test subjects. Impressions for working casts were taken, and construction bites were prepared for the fabrication of eight functional appliances of various designs for each individual test subject. These appliances had eight design variations. There were three tests: one for speech effects, one for initial acceptance, and one for final acceptance after wearing different scales. Results Overall, the correlation between the quality of speech and pronunciation after wearing the appliance and the type of functional appliance was statistically significant. The quality of speech and pronunciation after wearing the appliance was maximum in frequency range 1 (FR1), while it was minimum in the medium-size activator. The difference was statistically significant (p=0.001). Overall, the correlation between the comfort and acceptability of functional appliances after wearing them and the type of functional appliance was statistically significant. The acceptance of functional appliances after wearing was maximum in FR1, while it was minimum in the medium-size activator. The difference was statistically significant (p=0.001). Overall, the correlation between the type of functional appliance and initial acceptance was significant statistically, with the maximum initial acceptance in medium-sized activators and the minimum initial acceptance in small bionators (p=0.001). Conclusion The study's findings show that patient acceptance of various kinds of functional appliances varies significantly.
More Related Videos
07:32Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment
Published on: February 23, 2024
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024