Related Experiment Video
Updated: Jul 7, 2025

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Applying a risk assessment guided evaluation for verifying comprehensive two-dimensional gas chromatography to
Lukas Schwalb1,2, Ole Tiemann1,3, Uwe Käfer1,2,4
1Joint Mass Spectrometry Centre (JMSC), Chair of Analytical Chemistry, University of Rostock, Rostock, Germany.
Abstract:
The reliability of analytical results is critical and indispensable when applied in regulated environments such as the pharmaceutical industry. Therefore, analytical workflows must be validated. However, validation guidelines are often designed for quantitative targeted analysis and rarely apply to qualitative untargeted approaches. In this study, we employ a risk assessment approach to identify critical parameters which might influence the qualitative results derived by online derivatisation - comprehensive two-dimensional gas chromatography coupled to a high-resolution time-of-flight mass spectrometer (GC × GC-HR-ToF-MS) for the analysis of the active pharmaceutical ingredient (API) sodium bituminosulfonate (SBS). To show the complexity and feasibility of such an approach, we focus on investigating three potential risk factors: sample preparation, vapourability, and the thermal stability of sulfonates. Through the individual evaluation of these potential risk factors due to the application of sample preparation approaches and thermal gravimetric analysis (TGA), we demonstrate the high derivatisation efficiency and repeatability of the online derivatisation method and confirm the absence of derivatisation-induced side reactions. In addition, we also show the potential thermal instability of an incompletely derivatised API. To address the limitation of these individual assessments, we applied a holistic evaluation step with negative electrospray ionisation Fourier transform ion cyclotron resonance mass spectrometry (ESI( -) FT-ICR MS) as an orthogonal technique. This confirms that most of the API is detected via the presented GC-based method. Thereby, we demonstrated the practical feasibility of the risk assessment-based approach to ensure the validity of the qualitative data for a complex untargeted method.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:49On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-II