Related Concept Videos

Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

7.0K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
7.0K
IR Spectrometers01:25

IR Spectrometers

1.2K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.2K
IR Frequency Region: Fingerprint Region01:03

IR Frequency Region: Fingerprint Region

902
IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the...
902

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Comparative effects of platelets and plasma-derived mitochondria in early-phase Achilles tendon inflammation.

Regenerative biomaterials·2026
Same author

Melanocortin 1 receptor-targeted peptide-functionalized liposomes for enhanced melanocyte-preferential drug delivery and anti-melanogenic efficacy.

Journal of materials chemistry. B·2026
Same author

Association Between Remnant Cholesterol and Muscle Mass and Quality: Insights from Muscle Quality Mapping and Abdominal Computed Tomography.

Diagnostics (Basel, Switzerland)·2026
Same author

Clinical Implications of the Langer's Axillary Arch Muscle in Breast Cancer Patients.

Journal of breast cancer·2026
Same author

Erratum to "Glycogen Phosphorylase Inhibitor Promotes Hair Growth via Protecting from Oxidative-Stress and Regulating Glycogen Breakdown in Human Hair follicles" [Biomol Ther 32(5), 640-646 (2024)].

Biomolecules & therapeutics·2026
Same author

Integrated analysis of age-related microbiome and metabolites reveals youth-associated metabolites in young Korean women's skin.

International microbiology : the official journal of the Spanish Society for Microbiology·2026

Related Experiment Video

Updated: Jul 7, 2025

High-definition Fourier Transform Infrared FT-IR Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
11:05

High-definition Fourier Transform Infrared FT-IR Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology

Published on: January 21, 2015

33.3K

Enhancing spatial resolution in Fourier transform infrared spectral image via machine learning algorithms.

Mina Lim1,2, Kyu Ho Park3, Jae Sung Hwang3

  • 1Advanced Analysis and Data Center, Korea Institute of Science and Technology, Seoul, 02792, Republic of Korea.

Scientific Reports
|December 20, 2023
PubMed
Summary

Machine learning algorithms reduce noise and enhance spatial resolution in Fourier transform infrared (FT-IR) spectroscopy. This approach achieves high-quality data from single scans, improving research efficiency by minimizing repetitive measurements.

More Related Videos

A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors
11:15

A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors

Published on: May 30, 2016

25.2K
Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

8.5K

Related Experiment Videos

Last Updated: Jul 7, 2025

High-definition Fourier Transform Infrared FT-IR Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
11:05

High-definition Fourier Transform Infrared FT-IR Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology

Published on: January 21, 2015

33.3K
A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors
11:15

A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors

Published on: May 30, 2016

25.2K
Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

8.5K

Area of Science:

  • Analytical Chemistry
  • Spectroscopy
  • Data Science

Background:

  • Fourier transform infrared (FT-IR) spectroscopy is crucial for chemical structure characterization.
  • Signal noise and low concentrations often limit the signal-to-noise ratio (SNR) in FT-IR analysis.
  • Traditional methods to improve SNR involve repetitive measurements and data superposition.

Purpose of the Study:

  • To investigate the application of machine learning for noise reduction and spatial resolution enhancement in FT-IR spectroscopy.
  • To achieve high-quality FT-IR spectral data from single scans, comparable to results from multiple superimposed scans.
  • To improve the efficiency of chemical structure characterization using FT-IR.

Main Methods:

  • Applied machine learning algorithms, specifically principal component analysis (PCA) and non-negative matrix factorization (NMF), for dimensionality reduction on FT-IR spectral image data.
  • Utilized Gaussian fitting in conjunction with machine learning algorithms to enhance the spatial resolution of mapping images.
  • Analyzed FT-IR spectral image data acquired from single scans.

Main Results:

  • Achieved high-quality FT-IR spectral data from single scans, comparable to results obtained from 64 superimposed scans.
  • Demonstrated significant enhancement in the spatial resolution of mapping images correlated to chemical structures.
  • Showcased that dimensionality reduction techniques further improve the spatial resolution of mapping images acquired through relative intensity.

Conclusions:

  • Machine learning algorithms (PCA, NMF) can effectively reduce noise and enhance spatial resolution in FT-IR spectroscopy.
  • Single-scan FT-IR analysis with ML optimization offers comparable quality to traditional multi-scan methods.
  • Optimizing research data through ML-driven noise reduction and spatial resolution enhancement can significantly improve research efficiency by reducing redundant measurements.