Related Experiment Video
Updated: Jul 7, 2025

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
Data reconciliation connected to guard bands to set specification limits related to risk assessment for
Wagner do Prado Pereira1, Luciana Carvalheira2, José Marques Lopes3,4
1Radiopharmacy, Américas Medical City, Av. Jorge Curi 550, 22775-001, Rio de Janeiro, Brazil.
Abstract:
Radiopharmaceuticals have been used to diagnose several diseases, particularly because the procedure is non-invasive. However, it is important that the correct amount of radiopharmaceutical is used to avoid inaccurate diagnostic results and suboptimal therapeutic outcomes. The amount of the radiopharmaceutical is measured when produced (by the supplier) and a second time (by the receiver), before it's use. When measured at the receiver, the result is corrected for its normal radioactivity decay. Even then, it is possible that both measurements should be considered nominal different or even statistically different when compared through various statistical tools. This research combines two innovative techniques in the field of clinical metrology. The first technique is data reconciliation, which not only enhances measurement accuracy but also reduces measurement uncertainty. The second technique involves using uncertainty information to establish specification limits for compliance assessments. In this way, our proposal aimed to minimize the risk of making incorrect decisions regarding the conformity of the concentration of radiopharmaceutical activity, that is, rejecting an item or batch that is within specification or accepting an item or batch that is outside of specification. A spreadsheet, based on these metrology fundamentals, is available to help the user with the calculations, presenting numerical and graphical results for some common radioisotopes. Reliable specification limits can be calculated and used to determine if the radiopharmaceutical is in accordance with its proposed application.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
09:07Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT