Natividad Rico Ríos1, Alison Bransfield1, Caroline M Joyce1
1Department of Clinical Biochemistry, Cork University Hospital, Cork, Republic of Ireland.
A case report of in vivo hemolysis in a female patient with Evans syndrome is described. The patient was admitted with anemia and jaundice and, during her 26-day hospital admission, had 83 samples taken for biochemistry analyses. The laboratory hemolytic index (HI) was frequently elevated due to persistent complement-mediated in vivo hemolysis despite multiple lines of therapy. Initially, the release of many biochemical parameters was blocked per the manufacturer´s recommendations and reported as "sample hemolyzed". The patient developed severe acute kidney injury, ultimately requiring dialysis. Automated and timely reporting of indicative creatinine and other biochemical results in the context of ongoing hemolysis, therefore, became essential to patient care. Following a review of literature from various sources, a laboratory algorithm was designed to ensure the timely release of numerical biochemical values, where possible, with appropriate interpretative comments appended. Biochemistry, hematology, and nephrology teams were in regular communication to ensure patient samples were rapidly identified, analyzed and validated according to the algorithm, informing timely, safe and appropriate patient care. Ultimately, the patient died due to multiple disease- and treatment-related complications. In conjunction with clinical users, laboratories should plan for situations, such as in vivo hemolysis, where significant unavoidable interferences in biochemistry methodologies may occur in an ongoing manner for certain patients. Reporting categorical or best-estimate biochemistry results in such cases can be safer for patients than failing to report any results. Interpretation of these results by clinical teams requires input from appropriately trained and qualified laboratory personnel.
A case report of in vivo hemolysis in a female patient with Evans syndrome is described. The patient was admitted with anemia and jaundice and, during her 26-day hospital admission, had 83 samples taken for biochemistry analyses. The laboratory hemolytic index (HI) was frequently elevated due to persistent complement-mediated in vivo hemolysis despite multiple lines of therapy. Initially, the release of many biochemical parameters was blocked per the manufacturer´s recommendations and reported as "sample hemolyzed". The patient developed severe acute kidney injury, ultimately requiring dialysis. Automated and timely reporting of indicative creatinine and other biochemical results in the context of ongoing hemolysis, therefore, became essential to patient care. Following a review of literature from various sources, a laboratory algorithm was designed to ensure the timely release of numerical biochemical values, where possible, with appropriate interpretative comments appended. Biochemistry, hematology, and nephrology teams were in regular communication to ensure patient samples were rapidly identified, analyzed and validated according to the algorithm, informing timely, safe and appropriate patient care. Ultimately, the patient died due to multiple disease- and treatment-related complications. In conjunction with clinical users, laboratories should plan for situations, such as in vivo hemolysis, where significant unavoidable interferences in biochemistry methodologies may occur in an ongoing manner for certain patients. Reporting categorical or best-estimate biochemistry results in such cases can be safer for patients than failing to report any results. Interpretation of these results by clinical teams requires input from appropriately trained and qualified laboratory personnel.
Related Concept Videos
Inborn Errors of Metabolism
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...