Related Experiment Video
Updated: Aug 18, 2026

PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
Determination of internal target volume with Cine-MRI sequence for prostate MRI-Guided radiotherapy
Ran Wei1, Bin Liang1, Kuo Men1
1National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Background:
In prostate radiotherapy, the intrafractional target motion negatively affects treatment accuracy. Generating internal target volume (ITV) using four-dimensional (4D) images may resolve the issue of intrafractional target motion induced by bladder filling and bowel movement. However, no 4D imaging techniques suitable for the prostate are currently available in clinical practice.
Purpose:
This study aimed to determine the ITV based on cine magnetic resonance imaging (MRI) sequence for intrafractional target motion management in prostate MRI-guided radiotherapy.
Materials And Methods:
A reference ITV was generated in simulation process. Then, the reference ITV was adapted with cine MRI sequence before online planning in each fraction. Finally, the reference ITV was updated with the cine MRI sequence acquired during beam delivery after each fraction. Cine MRI sequences and positioning three-dimensional (3D) MRI from 35 patients were retrospectively collected. Clinical target volume (CTV) coverage was computed according to the two-dimensional contour of CTV and ITV on cine MRI images. Relative target size was calculated as the ratio of the volume of ITV and CTV. Isotropic planning target volume (PTV; 5 mm margin) and anisotropic PTV (3 mm margin in the posterior direction and 5 mm margin in other directions) were generated for comparison.
Results:
The CTV coverage rate of the proposed ITV had a mean value of 98.61% ± 0.51%, whereas the CTV coverage rates of the isotropic and anisotropic PTVs were 97.43% ± 0.41% and 96.58% ± 0.73%, respectively. The proposed ITV had a relative target size of 1.79 ± 0.17, whereas the anisotropic and isotropic PTVs had relative target sizes of 1.92 ± 0.12 and 2.21 ± 0.19, respectively. For both the CTV coverage rate and target relative size, significant differences were observed between the proposed ITV and the other two PTVs (p < 0.05).
Conclusion:
The ITV achieved higher CTV coverage with smaller size than conventional isotropic and anisotropic PTVs, indicating that it can effectively deal with the intrafractional movement of the prostate.
Related Concept Videos
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging