Analysis of Periprocedural X-ray Exposure in Transarterial Radioembolization with Glass or Resin Microspheres
Constantin Ehrengut1, Johanna Vogt1, Jakob Leonhardi1
1Department of Diagnostic and Interventional Radiology, University of Leipzig Medical Center, 04103 Leipzig, Germany.
Abstract:
Background: Transarterial Radioembolization (TARE) is an effective treatment option for both primary and secondary liver malignancies. However, challenging anatomical conditions can lead to prolonged fluoroscopy times (FT), elevated doses of periprocedural X-radiation (DAP), and increased use of contrast agents (CAs). In this study, we examined the influence of our radiologists' experience and the choice of microspheres on X-ray exposure and CA doses in TARE. Material and Methods: Datasets comprising 161 TARE and 164 preprocedural evaluation angiographies (TARE-EVA) were analyzed. Our study focused on assessing DAP, FT, and CA concerning both microsphere types, the radiologist's experience, and whether the same radiologist performed both the TARE-EVA and the actual TARE. Results: In TARE, the use of resin microspheres resulted in significantly higher FT and CA compared to glass microspheres (14.3 ± 1.6 min vs. 10.6 ± 1.1 min and 43 ± 2.2 mL vs. 33.6 ± 2.1 mL, p < 0.05), with no notable differences in DAP (p = 0.13). Experienced radiologists demonstrated reduced FT/DAP, with a 19% decrease in DAP and 53% in FT during the evaluation angiography (p < 0.05) and a 49% reduction in DAP during the actual TARE (p < 0.05), with no statistical differences in FT. Performing TARE and TARE-EVA under the same radiologist led to a 43% reduction in DAP and a 25% decrease in FT (p < 0.05, respectively). Conclusions: To mitigate X-radiation exposure, it is advisable for radiologists to undergo thorough training, and, ideally, the same radiologist should conduct both the TARE and the TARE-EVA. While the use of glass spheres may decrease intraarterial CA, it does not significantly impact periprocedural X-ray exposure.
More Related Videos
09:11Y-90 Radioembolization and PD-1 Inhibitor as Neoadjuvant Treatment in Hepatocellular Carcinoma
Published on: May 24, 2024
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...