Oral Galvanism Side Effects: Comparing Alloy Ions and Galvanic Current Effects on the Mucosa-like Model
Natalia Chepelova1, Artem Antoshin1, Sergei Voloshin1
1Institute for Regenerative Medicine, Sechenov First Moscow State Medical University, 8-2 Trubetskaya St., Moscow 119048, Russia.
Journal of Functional Biomaterials
|December 22, 2023
Summary
Oral galvanism from dental alloys can cause harm. This study found galvanic current is the primary short-term damaging factor, though corrosion ions also contribute to toxicity.
Area of Science:
- Biomaterials Science
- Oral Medicine
- Toxicology
Background:
- Oral galvanism, arising from dental alloys, can lead to adverse effects like burning sensations and inflammation.
- The exact mechanisms behind oral galvanism-related side effects remain unclear, with direct current and alloy corrosion ions being suspected contributors.
Purpose of the Study:
- To systematically compare the damaging effects of galvanism (direct current + corrosion ions), direct current alone, and corrosion ions alone.
- To identify the key factors responsible for side effects of dental alloys using an in vitro model.
Main Methods:
- Utilized an in vitro mucosa-like model using immortalized human keratinocytes (HaCaTs).
- Compared the high-risk dental alloys Ti64-AgPd and NiCr-AgPd.
- Assessed the effects of synergistic galvanism, direct current, and corrosion ions separately.
Main Results:
- Galvanic current emerged as the primary damaging factor in cytotoxic processes related to galvanic coupling of intraoral appliances, particularly in the short term (28 days).
- The contribution of corrosion ions, specifically Ni2+, to synergistic toxicity was demonstrated.
- Corrosion ions may pose a significant danger in the long term.
Conclusions:
- Galvanic current is likely the leading cause of short-term cytotoxic effects from dental alloy interactions in the oral environment.
- Corrosion ions, such as Ni2+, play a role in the combined toxicity and could be a significant long-term risk factor.
- Understanding these factors is crucial for mitigating side effects associated with dental alloys.
Related Concept Videos
Voltaic/Galvanic Cells
57.3K
Spontaneous Chemical Reactions
Spontaneous redox reactions occur abundantly in nature. The chemical reaction occurring in a disposable AA battery powering our remote controls is one such example of a spontaneous redox reaction. Another example is the immersion of coiled copper wire into an aqueous silver nitrate solution. The reaction shows a gradual, visually impressive color change from colorless to bright blue and the formation of a grey precipitate on the copper wire. In this experiment,...
Spontaneous redox reactions occur abundantly in nature. The chemical reaction occurring in a disposable AA battery powering our remote controls is one such example of a spontaneous redox reaction. Another example is the immersion of coiled copper wire into an aqueous silver nitrate solution. The reaction shows a gradual, visually impressive color change from colorless to bright blue and the formation of a grey precipitate on the copper wire. In this experiment,...
57.3K
Voltammetry: Factors Affecting Measurements
157
A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...
157
Galvanometer
2.2K
Common devices, including car instrument panels, battery chargers, and inexpensive electrical instruments, measure potential difference (voltage), current, or resistance using a d'Arsonval galvanometer. This electromechanical instrument is also known as a moving coil galvanometer.
The galvanometer consists of two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform...
The galvanometer consists of two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform...
2.2K
Standard Electrode Potentials
43.9K
On comparing the reactivity of silver and lead, it is observed that the two ionic species, Ag+ (aq) and Pb2+ (aq), show a difference in their redox reactivity towards copper: the silver ion undergoes spontaneous reduction, while the lead ion does not. This relative redox activity can be easily quantified in electrochemical cells by a property called cell potential. This property is commonly known as cell voltage in electrochemistry, and it is a measure of the energy which accompanies the charge...
43.9K
Controlled-Current Coulometry: Overview
208
Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
208
Voltammograms: Overview
211
Voltammograms are current plots as a function of applied potential, offering insights into electrochemical systems. The shape of a voltammogram depends on how the current is measured and whether convection (heat transfer by fluid movement) is present or absent.
Shapes of Voltammograms
Shapes of Voltammograms
211