Related Experiment Video
Updated: Jul 7, 2025

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Microleakage of chairside moulded, 3D-printed and milled provisional restorations using a curve-fit approach
Keshia Reyes1, Polina Plaksina1, Abdullah Barazanchi1
1Sir John Walsh Research Institute, University of Otago, Dunedin, New Zealand.
Abstract:
The purpose of this study was to evaluate and measure the microleakage inhibiting quality of provisional restorations manufactured using computer-aided manufacturing, 3D printing, and chairside molded provisional restorative materials. Fifteen provisional restorations each from 3D printed, milled, and chairside molded were manufactured. All restorations were cemented onto sintered zirconia abutment dies and adhered with zinc-oxide non-eugenol temporary cement. Artificial aging was conducted by thermocycling for 800 cycles to simulate 1 month of clinical use. All specimens were submerged in 2% (w/w) methylene blue for 24 hours at 37°C, sectioned, and analyzed digitally for the distance of dye penetration through image analysis. The data were analyzed using the Kruskal-Wallis test with Dunn-Bonferroni post-hoc. Significant differences in dye penetration depth were observed between all groups except milled vs chairside molded. Light microscopy revealed differences in mean cement thickness for 3D printed, milled, and chairside molded of 83.6 µm (1σ = 31.9 µm), 149.1 µm (1σ = 88.7 µm) and 137.9 µm (1σ = 67.2 µm) respectively. Conclusion: 3D printed provisional restorations were found to have the least amount of microleakage compared to milled and chairside molded provisional restorations.