Related Experiment Video
Updated: Jul 7, 2025

Intratracheal Administration of Dry Powder Formulation in Mice
Published on: July 25, 2020
Does mixing inhaler devices lead to unchecked inhaler technique errors in patients with COPD? Findings from the
Lars Dijk1, Marjan Kerkhof1, Merijn Driessen1
1General Practitioners Research Institute, Groningen, The Netherlands.
Background:
Patients with chronic obstructive pulmonary disease (COPD) may be prescribed multiple inhalers that require different techniques for optimal performance. Mixing devices has been associated with poorer COPD outcomes suggesting that it leads to inappropriate inhaler technique. However, empirical evidence is lacking.
Aims:
Compare the nature and frequency of dry powder inhaler (DPI) technique errors in patients with COPD using (1) a single DPI or (2) mixed-devices (a DPI and pressurised metered dose inhaler (pMDI)).
Methods:
Data from the PIFotal study-a cross-sectional study on Peak Inspiratory Flow in patients with COPD using a DPI as maintenance therapy, capturing data from 1434 patients on demographic characteristics, COPD health status and inhaler technique-were used to select 291 patients using mixed-devices. Frequency matching based on country of residence and DPI device type was used to select 291 patients using a DPI-only for comparison. Predetermined checklists were used for the evaluation of DPI video recordings and complemented with additional errors that were observed in ≥10%. Error proportions were calculated for the (1) individual and total number of errors, (2) number of critical errors and (3) number of pMDI-related errors.
Results:
The study sample contained 582 patients (mean (SD) age 69.6 (9.4) years, 47.1% female). DPI technique errors were common, but not significantly different between the groups. The majority of patients made at least one critical error (DPI-only: 90.7% vs mixed-devices: 92.8%). Proportions of total, 'pMDI-related' and critical errors did not significantly differ between the groups.
Conclusion:
The nature and frequency of inhaler technique errors did not substantially differ between patients prescribed with a single DPI and mixed-devices. Currently, 'pMDI-related errors' in DPI use are not accounted for in existing checklists.
Trial Registration Number:
ENCEPP/EUPAS48776.
More Related Videos
Related Concept Videos
Inhaled Medications
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
COPD: Management Using Bronchodilators and Corticosteroids
Chronic Obstructive Pulmonary Disease-V: Management
Smoking Cessation
Drugs Used in Lower Respiratory Disorders: Overview
Bronchodilators, the first step of respiration enhancement, come in various forms, each with its own mechanism...
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...

