A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Comparison of Preoperative ECG Screening and Device-Based Vector Analysis in Patients Receiving a Subcutaneous
Szymon Budrejko1, Agnieszka Zienciuk-Krajka1, Ludmiła Daniłowicz-Szymanowicz1
1Department of Cardiology and Electrotherapy, Faculty of Medicine, Medical University of Gdansk, Smoluchowskiego 17, 80-214 Gdansk, Poland.
Abstract:
Background and Objectives: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) provide protection against sudden cardiac death from outside the cardiovascular system. ECG screening is a prerequisite for implantation, but the reproducibility of its results post-operatively in the device is only partial. We aimed to compare the results of ECG screening with device-based sensing vector analysis. Materials and Methods: We screened the hospital records of all S-ICD recipients in our clinic. All of them had pre-operative ECG screening performed (primary, secondary, and alternate vectors). The results were compared with device-based vector analysis to determine the relation of the pre- and post-operative vector availability. Results: Complete ECG screening and device-based vector analysis were obtained for 103 patients. At least two acceptable vectors were found in 97.1% of the patients pre-operatively and in 96.1% post-operatively. When comparing vectors in terms of agreement (OK or FAIL) pre- and post-operatively, in 89.3% of the patients, the result for the primary vector was the same in both situations; for the secondary, it was in 84.5%, and for the alternate, it was in 74.8% of patients, respectively. In 55.3% of patients, all three vectors were labeled the same (OK or FAIL); in 37.9%, two vectors had the same result, and in 6.8%, only one vector had the same result pre- and post-operatively. The number of available vectors was the same pre- and post-operatively in 62.1% of patients, while in 15.5%, it was lower, and in 22.3% of patients, it was higher than observed during screening. Conclusions: Routine clinical pre-operative screening allowed for a good selection of candidates for S-ICD implantation. All patients had at least one vector available post-operatively. The final number of vectors available in the device-based analysis in most patients was at least the same (or higher) than during screening. The repeatability of the positive result for a single vector was high.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...